hi , my MT45FP has been running on an independent lithium battery that run down flat, since it has been recharged the fridge runs on freezing while set on cooler only,, any ideas please folks? Currently it is no good for my beers,,
cheers..
Have you tried on 240v and maybe try on a AGM battery to see if it runs normal?
will right now.. thanks
in the time i disconnected it (30mins?) and got back to it just then, it had dropped from -19 to -4, and is now running on the 240, i will watch to see what happens,, cheers
just re-checked, set on cooling, it has dropped to -8 now,, ?
i will pull the fuse to check it, if it fails will the fridge revert to freeze?
1/2 hour on with 240v, setting on lowest cool (close to off) fridge still on -8 temp,, ?
I have the same problem. I believe it is the thermistor. I removed it and tested the resistance of the thermistor and it is infinite resistance. It is my understanding that the resistance should be 2ohm at 25C. I have ordered a new Thermistor and will be swaping it with the old one once it arrives.
hi Martin, i ended up fixing mine the same way,,,,,,,,, thank you & cheers All,,,,,,,,,,,
Wondering what year would a model number MT45F-G4-P HAVE BEEN MADE?
Not sure of all the models & years of manufacture, but Engel themselves are very helpful. Just give them a call.